Using the CR8e
Options Menu
48
NOTE:
When the SAF-TE card is set to off bus, LEDs and other error reporting
are not driven by the subsystem’s off bus SAF-TE card, but are reported
and controlled from the “Master” subsystem’s SAF-TE card.
Reset Default IDs Selection
Choosing the “Reset Default IDs” option will reset all subsystem SCSI IDs to their
factory default settings.
The default drive ID settings when a dual-bus module is installed are 0, 1, 2, and
4 for both the upper and lower drive groups.
The default drive ID settings when a single-bus module is installed are 0, 1, 2, 4,
5, 6, 8, and 9.
The default SCSI ID for the SAF-TE card is ID 3. SCSI ID 7 is reserved for the
host bus adapter.
NOTE:
You must power cycle the subsystem for the SCSI IDs changes to take
effect. Also be sure to power cycle the host computer. If a PCI-based
RAID Controller is being used and the host is not power cycled, it will
“kill” all drives in the array.
1 To reset the SCSI IDs, access the Main menu and choose Options Menu.
2 Use the up/down arrow buttons to select SCSI ID Menu and press the Enter
button.
3 Use the up/down arrow buttons to select RESET DEFAULT IDS.
4 Press the Escape button twice to return to the Main “Status OK” screen, then
power cycle the host computer and CR8e subsystem.
MENU ENTER ESCAPE
RESET DEFAULT IDS
nStor
SET UPPER SLOT IDS
SET LOWER SLOT IDS
SET SAFTE ID
MENU ENTER ESCAPE
DUAL BUS MODE
ALL SCSI IDS SET TO
EFFECT CHANGES)
(CYCLE POWER TO
nStor