Using the CR8e
Options Menu
46
Options Menu
From the Options Menu the following are available:
SCSI ID Menu
Heat Threshold
SAFTE Chain ID
Change Passcode
Unlock Options
SCSI ID Menu
From the SCSI ID Menu you can set SCSI IDs for drives attached to each of the
SCSI channels (lower slot and upper slot), and set the CR8e SAF-TE processor ID
(upper or lower bus if a Dual-bus module is installed).
You can manually set SCSI IDs for each group of drives from a pre-defined table of
IDs, see JP4 (SCSI ID Settings) on page 74 for a list of the possible ID combinations.
The SCSI IDs which are currently set will be flashing. The IDs will be assigned
sequentially beginning with the lowest device in the group.
NOTE:
Drive SCSI IDs cannot be set individually.
1 To manually set the SCSI IDs for the drive sets found in the upper or lower
slots, access the Main menu and choose Options Menu.
2 Use the up/down arrow buttons to select SCSI ID Menu and press the Enter
button.
3 Use the up/down arrow buttons to select either the Lower or Upper drive slot
IDs, or the SAFTE ID, and press the Enter button.
MENU ENTER ESCAPE
SCSI ID MENU
HEAT THRESHOLD
SAFTE CHAIN ID
CHANGE PASSCODE
nStor
MENU ENTER ESCAPE
nStor
RESET DEFAULT IDS
SET UPPER SLOT IDS
SET LOWER SLOT IDS
SET SAFTE ID