Using the CR8e
Options Menu
47
4 Use the up/down arrow buttons to make your SCSI ID group selection and
press the Enter button.
Note the flashing set of IDs, if present. These will be the group currently
configured.
5 Press the Escape button twice or the Menu button to return to the Main “Status
OK” screen, then power cycle the host computer and CR8e subsystem.
NOTE:
You must power cycle the subsystem for the SCSI IDs changes to take
effect.
To change the SAF-TE card SCSI ID, follow the five steps above, except select “Set
SAFTE ID” in step 3 and choose from “Set ID on Lower Bus” or “Set ID on
Upper Bus” in step 4. Use the up/down arrow buttons to change the ID value.
Since the subsystem is available in either a split SCSI bus design or as a single
SCSI bus, you can set the SAF-TE card SCSI ID for each bus if a conflict is
occurring. The default setting is SCSI ID 3 for each bus. The setting for SCSI
ID “OB” indicates Off Bus and is generally used when the subsystem is
installed in a “Slave” subsystem in a Master/Slave environment.
MENU ENTER ESCAPE
nStor
RESET DEFAULT IDS
SET UPPER SLOT IDS
SET LOWER SLOT IDS
SET SAFTE ID
MENU ENTER ESCAPE
0 1 2 3
0 1 2 4LOWER 4
4 5 6 7
4 5 6 8
5 6 7 8
nStor
MENU ENTER ESCAPE
SET ID ON UPPER BUS
SET ID ON LOWER BUS
nStor
MENU ENTER ESCAPE
ENTER TO SET NEW ID
ESC TO EXIT
PROCESSOR ID: 3
ARROWS CHANGE ID