Using the CR8e
Heat Threshold
49
Heat Threshold
NOTE:
The Heat Threshold value is pre-set at the factory and should not be
changed unless directed by nStor Technical Support. The default setting
is 116°F/47.°C.
Choose the Heat Threshold Menu to change the temperature value for the
thermal monitoring system. If the temperature exceeds the value set here, a
“Temperature Threshold Exceeded” screen will appear, see Internal Temp on
page 45.
1 Use the up/down arrow buttons to select Heat Threshold and press the Enter
button.
2 Using the up/down arrow buttons, change the temperature threshold setting.
The up arrow button will increase the temperature and the down arrow
button will lower the temperature threshold. The temperature value will
change by 2°C increments.
3 Press the Enter button the set the new temperature value.
4 Press the Escape button twice or press the Menu button to return to the Main
“Status OK” screen, then power cycle the host computer and CR8e
subsystem.
MENU ENTER ESCAPE
ENTER TO SET
ARROWS TO CHANGE
116°F / 47°C
ESC TO EXIT
nStor
MENU ENTER ESCAPE
nStor
SCSI ID MENU
HEAT THRESHOLD
SAFTE CHAIN ID
CHANGE PASSCODE