Installation
Fast Wide SCSI Mode
29
6 Connect the other end of the jumper cable to the Channel #0 SCSI connector
on the left side or lower I/O Interface card in the second cabinet.
7 Connect one end of a second jumper cable to the Channel #1 SCSI connector
on the left side or lower I/O Interface card in the first cabinet.
8 Connect the other end of the second jumper cable to the Channel 1 SCSI
connector on the left side or lower I/O Interface card in the second cabinet.
NOTE: SCSI termination is automatic and requires no user configuration. Refer
to “Termination” on page 21 for information on systems using DEC
Fault bus protocol.
9 Turn on the power to the CR8e. After the power-on self-test has completed,
Status and Channel Mode LEDs will be solid green.
10 Access the Options menu on the Operator Control Panel and choose the
SAFTE CHAIN ID selection. For each subsystem, identify which subsystem
will be the master cabinet and which will be the slave cabinet. (Generally, the
master cabinet will the subsystem connected to the controller.) Refer to
“SAFTE CHAIN ID” on page 50.
11 After setting the cabinet identifications you must power cycle the subsystem.
Observe normal power cycling precautions by waiting a minimum of five (5)
seconds before adding power again.
This will reset the SCSI IDs to a default setting that prevents a SCSI ID
conflict under normal conditions.
12 Power up your computer system and run your configuration program.
This completes the hardware installation.